High-speed, High-capacity Machine Vision System

CV-X Series

Easy Setup Guide

PLC Type: Communication Type: Reader Type: Communication Device: Sample Programs/ Setup Files: Setup Guides: S7-1500: PROFINET: SR-700/ BL1300.

User's Manual (PC Software) IV Series Vision Sensor 1 Getting Started 4 Settings Navigator (Setting the Judgment Condition) 7 Simulator 8 Controlling with the Input/Output Line 2 Installation and Connection 5 Operating/Adjusting. Instruction Manual: This describes the cautions upon use, names of parts, charging method, how to install the USB driver, specifications, and other information of the BT-1000/1500 Series. System Menu Operation Manual: This describes how to operate the system menu. Data Transfer Software Operation Manual. Cheap Keyence Plc Programming Manual, find Keyence Plc Programming Get Quotations PLC & HMI Programming: pin.

Control/Communication EtherNet/IP

(KEYENCE KV Series)

Easy Setup Guide: Control/Communication EtherNet/IP (KEYENCE KV Series)

1. Before Connecting EtherNet/IP

Page 3

2. Outputting the Measured Value/Judged Value

Page 6

3. Controlling the Controller

Page 9

4. Data Allocation

Page 15

5. Troubleshooting

Page 17

KEYENCE CORPORATION. Vision System Division

2

www.keyence.com

1. Before Connecting EtherNet/IP (EtherNet/IP) [Keyence KV Series]

This section describes how to establish EtherNet/IP.

[Important]

If it fails, establish a one-to-one connection between the PLC and CV-X, and follow this manual to configure the settings and check the operations.

Confirm that it operates properly, and change settings if necessary.

1.Checking the Global Settings of the CV-X100 Series

1From 'Global', select 'Communications & I/O' - 'Network'.

2 Change the Ethernet settings and then left-click

'OK'.

In this section, the set values below will be configured as an example (change the settings according to the target device).

IP Address: 192.168.0.10

Subnet Mask: 255.255.255.0

From 'Global', select 'Communications & I/O' - 'EtherNet/IP'.

Change the EtherNet/IP settings and then left-click 'OK'.

In this section, the set values below will be configured as an example (change the settings according to the target device).

Enable EtherNet/IP: Check this box.

Data Size: 496 bytes

Data Configurations: Set the desired data allocations and allocation offset for the bit address and byte address.

Decimal Point: Fixed point

Process Priority: Image First

Restart the controller.

365GB

KEYENCE CORPORATION. Vision System Division

3

www.keyence.com

2.Changing the KV-Series settings

1Start KV STUDIO with the PLC connected to the computer, and select 'New project' from the 'File' menu.

2 Enter the 'Project name', select the 'PLC model', and then press 'OK'.

A 'Confirm unit setting information' dialog appears.

3 Click 'Read unit setting'.

4 In the workspace, click the Ethernet/IP communication unit or CPU unit that will be connected to the CV-X100 Series to start 'Unit Editor'. Set up the IP Address of the KV Series in the 'Setup unit (2)' tab.

•IP Address: 192.168.0.20

•Subnet Mask: 255.255.255.0

5 Select 'Convert' - 'Auto-assign relay/DM' in the

Unit Editor to allocate a device.

When automatically allocated, the bit device is allocated to B (link relay) and the byte device is allocated to W (link register).

6 Click the icon in 'Setup unit (2)' to open

'EtherNet/IP settings'. Configure the CV-X100 Series and EtherNet/IP communication settings.

•Drag 'CV-X100' from the 'Unit list (1)' tab in 'EtherNet/IP settings' and drop it into the scan list to add it.

•In the 'Initial adapter settings' screen that is displayed after start up, enter the CV-100 Series IP Address (192.168.0.10) that was set in the CV-X100 Series global settings.

7 Divx dolby audio serial key. Save the changes and exit the 'EtherNet/IP settings' and Unit Editor.

8 Select 'Device comment edit window' from the

'Display' menu in KV STUDIO.

The 'Device comment edit' screen appears.

9 Click 'Details'.

The 'Register unit device' screen appears.

10 Confirm that the box for 'CV-X100' is checked in the 'Select unit' list, and then click 'Register'.

Device comments regarding CV-X100 are automatically registered.

KEYENCE CORPORATION. Vision System Division

4

www.keyence.com

11 Select 'Transfer to PLC' from the

'Monitor/Simulator' menu in KV STUDIO.

12 Restart both the CV-X100 Series and the KV Series.

When the connection is successful, the LINK LED (green) will start flashing on the KV Series Ethernet port.

Successful connection can also be confirmed by selecting 'Communications & I/O' - 'EtherNet/IP' in 'Global' on the CV-X100 Series, and checking the 'Cyclic Communication Status'.

If the LINK LED on the KV Series Ethernet port stays lit

(does not flash) or does not light

The EtherNet/IP may not be set up correctly, the cables may not be connected correctly, or the CV-X100 Series may not be started up. Check the connection equipment (if a crossover cable is being used as a LAN cable when connected directly, if the HUB is working, etc.)

KEYENCE CORPORATION. Vision System Division

5

www.keyence.com

2. Outputting the Measured Value/Judged Value (EtherNet/IP) [Keyence KV Series]

Outputting the Measured Value/Judged

1. Setting the output data (Output Settings)

Use the output settings to output the measured values and judged values. This section explains how to allocate the measured/judged values below as an example.

•TotalStatus Value

•T100: Position Adjustment with Shading Pattern (position X)

•T100: Position Adjustment with Shading Pattern (position XY)

•T101: Area

•T102: OCR (Recognize Strings)

•T100: Position Adjustment with Shading Pattern (tool judgment value)

•T101: Area (tool judgment value)

•Program Time

•Date & Time

1 From the 'Output Settings' screen, left-click

'EtherNet/IP'.

The EtherNet/IP output settings screen appears.

2 Left-click the 'Byte Allocation Area' tab.

3 Left-click 'Select Data', select the items to output, and then left-click 'Add'.

4 Check the byte address for output.

•Whenallocating output data, the destination byte address is automatically displayed in 'Address'.

•The byte address starting position is the position allocated to 'Result Data1' on the 'Data Configurations' - 'Send-Data' - 'View List' screen. (In the example above, it is byte address 048.)

2.Checking the format for output to the byte address, and the relationship between the byte address and the link register (W)

1Check an example of result data stored to the byte address.

The EtherNet/IP output settings are set so that the result data shown below is output.

Adobe illustrator cs5 full version with crack. •Total Status Value

•T100: Position Adjustment with Shading Pattern (position X)

•T100: Position Adjustment with Shading Pattern (position XY)

•T101: Area

•T102: OCR (Recognize Strings)

•T100: Position Adjustment with Shading Pattern (tool judgment value)

Keyence Kv Programming Manual

•T101: Area (tool judgment value)

Keyence Programming Manual

•Program Time

•Date & Time

2 Check the relationship between the byte address and the link register (W) in KV STUDIO.

Open 'EtherNet/IP settings' from the 'Setup unit (2)' tab in KV STUDIO Unit Editor, and click the plus sign

(+) next to 'Class1' for the registered CV-X100 to check the allocation status of the device. (In the notation, output from CV-X100 is treated as 'IN (input)'.)

•Checkthe range (hexadecimal)of the linkrelay

(B)/link register (W) allocated to the registered CV-X100 Series controller. (The range can also be changed as desired by clicking 'Edit'.)

Keyence Kv Series Programming Manual

•Byte addresses 0000-0011 are for the link relay (from B0000 onwards), and byte addresses from 0012 onwards are for the link register. Allocation begins at the start from W0000, with 1 register used for each 2-byte address.

Keyence Sz V04x Programming Manual

KEYENCE CORPORATION. Vision System Division

6

www.keyence.com