Using the 830B Digital Multimeter in the Home. A digital multimeter, sometimes known as a digital voltmeter or DVM (slightly inaccurately as it measures amps and ohms as well as volts), is an instrument which is used for making electrical and electronic measurements. ANENG A830L Ψηφιακό Πολύμετρο DC AC Τάση Δίοδος Freguency Transistor Tester ANENG SMD Chip Component LCR Testing Tool Multimeter Pen Tweezer Red COD. Multimeter technical features and parameters. 100% brand new and high quality. The Digital Multimeter is a practical tool for electrician use. It is easy to operate and the readings indicated directly on the screen. It can be use to overhaul all kinds of circuit boards. It is also an ideal teaching instrument for students. 15mm high LCD Display. AU$15.08 AU$20.57 27% Off ANENG A830L Digital Multimeter DC AC Voltage Diode Freguency Transistor Tester 249 reviews COD AU$59.39 AU$83.69 29% Off ANENG AN870 Auto Range Digital Multimeter 19999 Counts True-RMS NCV AC/DC Voltage Green 12 reviews COD.

Summary of Contents

Re: New ANENG multimeter « Reply #17 on: July 25, 2017, 12:09:24 am » Worse is that problem with switching it between AC and DC modes with a biased AC signal. Summary of Contents1 Fluke Multimeter User Manual2 Klein Multimeter User Manual3 Mastech Multimeter User Manual4 Craftsman Multimeter User Manual5 Amprobe AM-530 Multimeter User Manual6 Fieldpiece HS33 Multimeter User Manual7 Tacklife CM02A Multimeter User Manual8 UEi Test instruments DL369 Multimeter User Manual9 Extech EX330 Autoranging mini Multimeter User Manual10 Etekcity MSR-C600 digital.

Fluke Multimeter User Manual

Aneng a830l manual
Fluke ManualLinks
Fluke 115 Compact True-RMS digital multimeterDownload
Fluke 117 Electricians True RMS MultimeterDownload
Fluke 87-V digital multimeterDownload
Fluke 101 Basic digital best multimeter for electronics hobbyistDownload
Fluke 116/323 KIT HVAC Multimeter and clamp meter combo kitDownload
Fluke 323 True-RMS Clamp meterDownload
Fluke 77-IV automotive digital multimeterDownload

Klein Multimeter User Manual

Klein ManualLinks
Klein Tools CL800 digital clamp meterDownload
Klein Tools MM700 digital multimeterDownload
Klein Tools MM400 digital multimeterDownload
Klein Tools 69149 electrical test kitDownload
Klein Tool MM500 digital MultimeterDownload

Mastech Multimeter User Manual

Mastech ManualLinks
Mastech MS8268 Series digital multimeterDownload
Mastech MS8229 digital multimeterDownload
Mastech MS8264 digital multimeterDownload
Mastech MS2115A/B digital MultimeterDownload

Craftsman Multimeter User Manual

Craftsman ManualLinks
Craftsman 34-82141 digital multimeterDownload
Craftsman 34-82007 digital multimeterDownload
Craftsman digital multimeter with AC voltage detectorDownload

Amprobe AM-530 Multimeter User Manual

Amprobe AM-530 ManualLinks
Amprobe AM-530 TRMS electrical contractor multimeterDownload

Aneng A830l Multimeter

Fieldpiece HS33 Multimeter User Manual

Fieldpiece HS33 ManualLinks
Fieldpiece HS33 multimeter for HVACDownload

Tacklife CM02A Multimeter User Manual

Aneng Multimeter A830l User Manual Download Windows 7

Tacklife CM02A ManualLinks
Tacklife CM02A autoranging multimeterDownload

UEi Test instruments DL369 Multimeter User Manual

UEi Test instruments DL369 ManualLinks
UEi Test instruments DL369 clamp on meterDownload

Aneng Multimeter A830l User Manual Downloads

Extech EX330 Autoranging mini Multimeter User Manual

Aneng An8002 User Manual

Extech EX330 ManualLinks
Extech EX330 Autoranging mini multimeterDownload

Etekcity MSR-C600 digital clamp meter Multimeter User Manual

Etekcity MSR-C600 ManualLinks
Etekcity MSR-C600 digital clamp meter multimeterDownload

Aneng Multimeter A830l User Manual Download Windows 10

Download or browse on-line these Operation & User’s Manual for Aneng Q1 Multimeter.

Aneng Q1 Manual Information:

This manual for Aneng Q1, given in the PDF format, is available for free online viewing and download without logging on. The guide contains 26 pages, and the size of the file at download is . The document type is Operation & User’s Manual.

Summary of Contents

[Page 1] Aneng Q1 Manual

All rights reserved. Specifications are subject to change without notice. User Manual ..

[Page 2] Aneng Q1 Manual

LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditio..

[Page 3] Aneng Q1 Manual

Table of Contents Page Introduction.............................1 Safety Information........................1 Instrument Overview.....................

[Page 4] Aneng Q1 Manual

Maintenance............................15 Clean the Product.....................15 Replace the Batteries..................15 Replace the Fuses....................16 Sp..

[Page 5] Aneng Q1 Manual

Introduction This product is a 9999 counts true RMS auto- ranging digital multimeter. It is operated all by buttons with a triple display. Safety Information To avoid possible electrical shock, fire, or personal injury, please read all safety informa..

[Page 6] Aneng Q1 Manual

• Keep fingers behind the finger guards on the probes. • When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service. /asphalt-hack-204-serial-key.html. • Disconnect the test leads from the circuit before changin..

[Page 7] Aneng Q1 Manual

3 LCD Display ① Auto range. The product selects the range with the best resolution. ② Manual range. The user selects the range. ③ Display shows maximum reading. ④ Relative mode. ⑤ Diode test. ⑥ Continuity test. ⑦ Displ..

[Page 8] Aneng Q1 Manual

4 ⑪ Frequency test. (Hertz) ⑫ Temperature test. (Celsius) ⑬ Temperature test. (Fahrenheit) ⑭ Analog bar graph. ⑮ Resistance test. (Ohm) ⑯ Current test. (Ampere) ⑰ Voltage test. (Volt) ⑱ Primary measurement disp..

[Page 9] Aneng Q1 Manual

5 Function Buttons ① ② ③ ④ ⑤ ⑥ ⑦ ① Push for more than 2 seconds to turn on/off the product. • The product automatically powers off after 5 minutes of inactivity. • The built-in beeper beeps 5 times 1 minute before auto p..

[Page 10] Aneng Q1 Manual

6 ② Push once to hold the current reading on the display ; push again to continue normal operation . Push for more than 2 seconds to enter the relative mode. The product will store the present reading as a reference for subsequent rea..

[Page 11] Aneng Q1 Manual

⑦ Push this button when the product is at the setting of ACV, the primary measurement display will show the current frequency (1 ~100kHz) while the secondary measurement display will show the current duty cycle. Push this button when th..

[Page 12] Aneng Q1 Manual

Input Terminals 8 A mA Input terminal for AC/DC current measurements to 9.999A. μA Input terminal for AC/DC current measurements to 999.9μA. COM Common (return) terminal for all measurements . VΩHz Input terminal for the measurements..

[Page 13] Aneng Q1 Manual

9 Measurements Instruction Measure AC/DC Voltage 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. To measure voltage under 99.99mV, push , push once to measure DCmV, push twice to measure ACmV. To measure ..

[Page 14] Aneng Q1 Manual

10 2. Push to toggle between DCA and ACA. 3. Break the circuit path to be measured, connect the test leads across the break and apply power. 4. Read the measured current on the display. Measure Resistance 1. Connect the black test lead to the COM Ter..

[Page 15] Aneng Q1 Manual

11 Test Diodes and Continuity 1. Connect the black test lead to the COM Terminal and the red lead to the VΩHz Terminal. 2. Push twice to enter the Diode/Continuity Mode. 3. To test continuity, touch the probes to the desired test points of the circu..

[Page 16] Aneng Q1 Manual

2. Push three times to enter the Capacitance Mode. 3. Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested. 4. Read the measured capacitance value on the display once the reading is stablized. ..

[Page 17] Aneng Q1 Manual

3. When the frequency to be measured is between 100kHz and 500MHz, push twice to enter the ACmV Mode; touch the probes to the desired test points, and the secondary measurement display will show the frequency; then push , the primary measurement disp..

[Page 18] Aneng Q1 Manual

14 2. Touch the probes to the desired test points. 3. Read the measured temperature on the display. Test NCV 1. Push twice to enter the NCV Mode. 2. Hold the product and move it around, the built- in beeper will beep when the inner sensor detects AC ..

[Page 19] Aneng Q1 Manual

Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, and service instructions. Clean the Product Wipe the product with..

[Page 20] Aneng Q1 Manual

2. Loosen the screw on the battery door and remove the battery door. 3. Replace the used batteries with new batteries of the same type. 4. Place the battery door back and fasten the screw. Replace the Fuses When a fuse is blown or do not work properl..

[Page 21] Aneng Q1 Manual

Specifications 17 General Specifications Display (LCD) 9999 Counts Ranging Auto/Manual Material ABS+TPE Update Rate 3 Times/Second Ture RMS √ Data Hold √ Backlight √ Low Battery Indication √ Auto Power Off √ Mechanical..

[Page 22] Aneng Q1 Manual

Electrical Specifications 18 Function Range Resolution Accuracy DC Voltage (V) 999.9mV 0.1mV ±(0.5%+3) 9.999V 0.001V 99.99V 0.01V 999.9V 0.1V DC Voltage (mV) 9.999mV 0.001mV 99.99mV 0.01mV AC Voltage (V) 999.9mV 0.1..

[Page 23] Aneng Q1 Manual

19 Function Range Resolution Accuracy DC Current (mA&A) 999.9mA 0.1mA ±(1.0%+3) 9.999A 0.001A DC Current (μA) 99.99μA 0.01μA ±(0.8%+3) 999.9μA 0.1μA AC Current (mA&A) 999.9mA 0.1mA ±(1.2%+3) 9.999A 0.001A AC..

[Page 24] Aneng Q1 Manual

Function Range Resolution Accuracy Capacitance 9.999nF 0.001nF ±(5.0%+20) 99.99nF 0.01nF ±(2.0%+5) 999.9nF 0.1nF 9.999μF 0.001μF 99.99μF 0.01μF 999.9μF 0.1μF 9.999mF 0.001mF ±(5.0%+5) Frequency (Measures only to 100kH..

[Page 25] Aneng Q1 Manual

21 Function Range Resolution Accuracy Temperature ( -20~1000) ℃ 1 ℃ ± (2.5%+5 ) ( -4~1832)℉ 1 ℉ Diode √ Continuity √ NCV √ ..